title: "How to write an intensity or cumulative intensity function for vectorized models"
author: "TA Trikalinos"
date: "2026-08-28"
output: rmarkdown::html_vignette
vignette: >
  %\VignetteIndexEntry{How to write an intensity or cumulative intensity function for vectorized models}
  %\VignetteEngine{knitr::rmarkdown}
  %\VignetteEncoding{UTF-8}
---

```{r, include = FALSE}
set.seed(20260828)
knitr::opts_chunk$set(
  collapse = TRUE,
  comment = "#>"
)
library(nhppp)
```

## What this vignette shows

The vectorized samplers take user functions in two roles: an **intensity**
`lambda` for the thinning samplers (`vdraw_intensity()`,
`vdraw_intensity_step()`), and a **cumulative intensity** pair
`Lambda` / `Lambda_inv` for the inversion sampler
(`vdraw_cumulative_intensity()`). This vignette states the calling contract
these functions must satisfy, shows the canonical way to pass parameters --
including parameters that differ across the simulated point processes -- and
collects the idioms and anti-patterns.

## The calling contract

Every user function is called **elementwise-vectorized**: it receives an array
of time points (or of $\Lambda$-values, for `Lambda_inv`) and must return an
object of the same shape, computed element by element. The samplers call

- `lambda(t)` or `lambda(t, a)`,
- `Lambda(t)` or `Lambda(t, a)`, and `Lambda_inv(z)` or `Lambda_inv(z, a)`,

where `a` is the argument container you supplied (next section), passed as the
**second positional argument**; the name of the second formal is yours to
choose. When you supply no container the function is called with a single
argument, so a plain closure works:

```{r closure}
l <- function(t) 0.5 * sqrt(t)
Z <- vdraw_intensity(
  lambda = l,
  lambda_maj_matrix = matrix(1.2, nrow = 100, ncol = 5),
  rate_matrix_t_min = 1, rate_matrix_t_max = 5
)
```

The shape of the first argument depends on the sampler: the thinning samplers
pass a matrix of candidate times with **one row per point process**; the
inversion sampler passes a two-column matrix of interval bounds to `Lambda`
and a matrix of $\Lambda$-values to `Lambda_inv` (also one row per process).
Elementwise arithmetic preserves shape automatically, so you rarely need to
think about it -- but it matters for how per-process parameters align, below.

## Passing parameters: the structured container

All of the function's parameters live in one container with two channels (slots):

```{r container-shape, eval = FALSE}
lambda_args = list(
  shared   = list(...), # row-invariant parameters, any type; stored ONCE
  row_args = data.frame(...) # one row per point process
)
```

- `shared` holds anything that is the same for every point process: scalars,
  vectors, matrices, spline bases, fitted model objects. It is never
  replicated across processes, so a large shared object costs its size once
  -- not once per process.
- `row_args` holds parameters that vary by point process: a `data.frame` (or
  `data.table` -- accepted as-is, read-only, never coerced or copied) with
  **one row per point process**, in the same order as the rows of the rate or
  majorizer matrix. The samplers validate the row count.

Inside your function, access both channels through the second argument:

```{r container-use}
l <- function(t, a) {
  a$shared$scale * t^a$row_args$exponent
}
n <- 1000
args <- list(
  shared = list(scale = 0.2),
  row_args = data.frame(exponent = seq(0.5, 1.5, length.out = n))
)
Z <- vdraw_intensity(
  lambda = l, lambda_args = args,
  lambda_maj_matrix = matrix(3, nrow = n, ncol = 5),
  rate_matrix_t_min = 1, rate_matrix_t_max = 5
)
```

**Why this aligns.** `t` arrives as an `n x M` matrix and
`a$row_args$exponent` is a length-`n` vector. R recycles vectors down the
columns of a matrix, and the matrix has one row per process -- so
`t^a$row_args$exponent` raises every entry of row $i$ to `exponent[i]`. This
column-major recycling is the relied-upon R idiom: write the function as if
`t` were a column of times for all processes at once, index nothing by hand.

**Rejection resampling is handled for you.** The conditioned thinning
samplers redraw only the point processes that failed the condition. In those
rounds your function receives `a` with `row_args` **already subset** to the
processes being redrawn, still aligned row-for-row with the candidate matrix.
Do not cache row indices between calls.

## Cumulative intensity pairs

`Lambda` must be continuous and increasing in `t` for each process, and
`Lambda_inv` must be its inverse. **One container serves both functions** --
there is a single `Lambda_args`, delivered to `Lambda` and `Lambda_inv`
alike, so write the pair against the same parameterization:

```{r inversion}
L <- function(t, a) (a$shared$r + a$row_args$d) * t
Li <- function(z, a) z / (a$shared$r + a$row_args$d)
n <- 1000
ctr <- list(
  shared = list(r = 0.4),
  row_args = data.frame(d = runif(n, 0, 0.4))
)
Z <- vdraw_cumulative_intensity(
  Lambda = L, Lambda_inv = Li,
  t_min = rep(0, n), t_max = rep(10, n),
  Lambda_args = ctr
)
```

Two additional requirements:

- **`NA` in, `NA` out.** The sampler calls `Lambda_inv` on `NA`-padded
  matrices (padding marks processes that have run out of events). Plain
  arithmetic propagates `NA` automatically; only special-case code
  (`if (z > ...)`, table lookups) needs care -- use vectorized constructs
  (`ifelse()`, `pmin()`/`pmax()`, `approxfun(..., rule = 2)`).
- With `output = "long"` on the conditioned path, `Lambda_inv` receives the
  event **vector** rather than a matrix, with `row_args` subset to one row
  per event. The same elementwise code covers both cases without change.

## Majorizers from the same function

`get_step_majorizer()` accepts the same container through `fun_args`, so the
sampler's `lambda` doubles as the input for majorizer construction -- no
hand-written wrapper:

```{r majorizer}
l <- function(t, a) a$shared$scale * t^a$row_args$exponent
n <- 1000
args <- list(
  shared = list(scale = 0.2),
  row_args = data.frame(exponent = seq(0.5, 1.5, length.out = n))
)
breaks_mat <- matrix(rep(seq(1, 5, length.out = 6), each = n), nrow = n)
lmaj <- get_step_majorizer(
  fun = l, breaks = breaks_mat, is_monotone = TRUE, fun_args = args
)
Z <- vdraw_intensity(
  lambda = l, lambda_args = args, lambda_maj_matrix = lmaj,
  rate_matrix_t_min = 1, rate_matrix_t_max = 5
)
```

If `lambda` ever exceeds the majorizer, the kernels stop with a "Majorizer"
error rather than silently sampling the wrong process -- prefer a slightly
generous majorizer over a tight one you have not verified.

## A complete example: heterogeneous population, both algorithms

A population where each person carries a frailty and a shape parameter, and
the same model is sampled by thinning (only `lambda` known) and by inversion
(closed-form `Lambda` and inverse): $\lambda_i(t) = w_i \, t^{p_i}$, so
$\Lambda_i(t) = w_i \, t^{p_i + 1} / (p_i + 1)$.

```{r worked-example}
n <- 2000
pop <- data.frame(
  w = rgamma(n, shape = 4, rate = 4), # frailty, mean 1
  p = runif(n, 0.5, 1.5)
)
args <- list(row_args = pop) # no shared channel needed; that is fine

l <- function(t, a) a$row_args$w * t^a$row_args$p
L <- function(t, a) a$row_args$w * t^(a$row_args$p + 1) / (a$row_args$p + 1)
Li <- function(z, a) (z * (a$row_args$p + 1) / a$row_args$w)^(1 / (a$row_args$p + 1))

breaks_mat <- matrix(rep(seq(0, 3, length.out = 7), each = n), nrow = n)
Z_thin <- vdraw_intensity(
  lambda = l, lambda_args = args,
  lambda_maj_matrix = get_step_majorizer(
    fun = l, breaks = breaks_mat, is_monotone = TRUE, fun_args = args
  ),
  rate_matrix_t_min = 0, rate_matrix_t_max = 3
)
Z_inv <- vdraw_cumulative_intensity(
  Lambda = L, Lambda_inv = Li,
  t_min = rep(0, n), t_max = rep(3, n),
  Lambda_args = args
)

# the two exact algorithms sample the same process
suppressWarnings(stats::ks.test(
  as.vector(Z_thin[!is.na(Z_thin)]),
  as.vector(Z_inv[!is.na(Z_inv)])
))$p.value
```

## Anti-patterns

- **Do not** replicate row-invariant parameters into `row_args`
  (`row_args = data.frame(scale = rep(0.2, n))`): it works, but costs `n`
  copies of what `shared` stores once. At $10^6$--$10^7$ processes this is
  real memory.
- **Do not** rely on the deprecated conventions: a flat
  `lambda_args = list(...)` (all-shared, kept working for released code), the
  nested `vector_arguments` element, and the separate `Lambda_inv_args` all
  emit deprecation warnings and will eventually be removed. New code uses
  `shared`/`row_args` and one `Lambda_args` for the pair.
- **Do not** write functions that expect the container by name
  (`function(t, lambda_args)` called as `lambda(t, lambda_args = ...)`): the
  delivery is positional; name the second formal whatever you like, but do
  not depend on the name.
- **Do not** modify `a` inside the function (in particular, no
  `data.table` by-reference operations on `a$row_args`): the container is
  read-only shared state; mutating it corrupts subsequent calls, including
  the resampling rounds of the conditioned thinning samplers.
- **Do not** branch on scalar tests (`if (t < 1) ...`) -- `t` is a matrix;
  use vectorized alternatives.